25mm2 3-core 250m rolls 76 kg each Aluminium Cable
Type 0.6/1kV LOBAC XLPE suitable for up to 120 vdc in the ground direct burial
Can be used in 2 runs at 75mm2 per run. You will need 2 drums of cable for this:
Each 250m run can deliver the following Watts at about 5% loss
- 24vdc (28 nominal) 250m long 150 W
- 48vdc (56 nominal) 250m long 600 W
- 120vdc (120 nominal) 250m long 2800W
Each 250m run can deliver the following Watts at about 10% loss
- 24vdc (28 nominal) 125m long 300 W
- 48vdc (56 nominal) 125m long 1200 W
- 120vdc (120 nominal) 125m long 5500W
As a rule of thumb for 8-10% loss for long runs using this cable:
Size in mm2 approx = current in cable (amps) x length (m) / 100
Divide this by 0.6 for aluminium wire
So for example 1700W at 56 vdc at 125m long is 1700/56 = 30.4 amps
Cable size = 30.4 x 125 / (100) = 38 mm2 copper or 63mm2 aluminium
Please note the automatic freight cost calculator for wire on rolls above 30kg will not be accurate as these items have to be sent by truck, please email for an accurate freight cost.
Please note the automatic freight cost calculator for wire on rolls above 30kg will not be accurate as these items have to be sent by truck, please email for an accurate freight cost.